Figure 2-20.  Heater Hose and Heater Inlet Adaptor.
2-13 EXTREME HOT CONDITIONS

TM-9-4310-396-13 Air Compressor Portable 5 CFM Model PD32T5 Manual
Page Navigation
  43    44    45    46    47  48  49    50    51    52    53  
TM9-4310-396-13 d.  Open all three vent louvers (1, Figure 2-21) on rear of complete top hood assembly. e.  Close all access doors (2) and latch. f.  Operate heater as directed on applicable heater instruction plate or heater manual. g.  After warm up by use of heater, start engine (reference 2-6.7). Figure 2-21.  Trailer Vent Louvers. 2-11.4 After Starting. a.  If heater was used, shut off heater and remove heater hose from compressor. b.  If gages are operating, return to normal operating procedures.  If gages are not operating, shut down engine and refer to PMCS Table 2-3. 2-12 DUSTY OR SANDY AREAS. CAUTION When operating in blowing dust or sand, protect compressor frame control panel with tarpaulins as necessary.  Be careful not to close off air intakes or vent louvers. Protect fuel supply from dust and dirt contamination.  Under extreme conditions, change filter element at least twice the normal frequency of once every six months or 500 hours, whichever comes first.  When not operating, close and cover compressor as tightly as possible. 2-12.1 Operation.  For startup and shutdown procedures, refer to paragraphs 2-6.7 and 2-6.8. 2-40