22-
CAUTION
Cont
Using standard commercial hex
head screws in place of high
tensile hex head screws to secure
the oil separator cover can
result in damage or failure of
the equipment during operation.
The original, or correct
replacement, high tensile hex
head screws must be used to
secure the oil separator cover to
meet ASME standards for
pressure vessels.
f. Install oil separator cover (108)
and align match marks. Install
eight hex head screws (110) and
new lock washers (111) (item 1,
section IV, chapter 4).