  12    13    14    15    16  17  18    19    20    21    22  
TM 9-4310-397-14 Table 2-1.  Preventive Maintenance Checks and Services for 16MS125 - Continued Location Item No. Interval Procedure Not Fully Mission Capable If: Item to Check/Service 5 Before Service Valves Inspect service valves (7).  Check Valves are cracked, (Double Discharge for smooth operation, cracks, and damaged, leak or bind. Valve) general condition. WARNING Radiator may be hot to touch and can cause serious personal injury.  Allow radiator to cool. Use a rag to unscrew cap. 6 Before Radiator Inspect radiator (8). a.  Check for obstruction, or Radiator is obstructed by damage to fins or tubes (9). dirt and debris or bent fins, tubes are damaged. b.  Check for leaks. Class III leak is found. c.  Service radiator by checking Coolant level is below coolant level.  If coolant is below the core. the core, top off with coolant to approximately midway between the core and fill neck as follows: (1) If operating at temperatures above 0°  F (-18°  C), mix a 60% antifreeze/water solution consisting of 77 oz antifreeze (item 7, section II, appendix E) with 51 oz water to yield one gallon of solution. 2-10