• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 4-1.  Preventive Maintenance Checks and Services for 16MS125
Preventive Maintenance Checks and Services for 16MS125 - Continued - TM-9-4310-397-14_75

TM-9-4310-397-14 Compressor Unit Reciprocating 10 CFM 175 PSI Diesel Engine Driven Trailer Mounted Model CUE67-6DY-TM Manual
Page Navigation
  56    57    58    59    60  61  62    63    64    65    66  
TM 9-4310-397-14 Table 4-1.  Preventive Maintenance Checks and Services for 16MS125 - Continued Location Item No. Interval Procedure Not Fully Mission Capable If: Item to Check/Service 2 Quarterly Engine, a.  Open access doors (1). Fuel Injection Pump b.  Inspect fuel injection pump (7) Injection pump damaged for any visible damage or leaks. or class III leak is found. c.  Close access doors (1). 3 Quarterly Engine, a.  Open access doors (1). Thermostat b.  Inspect thermostat housing (8) Thermostat damaged or for any visible damage or leaks. class III leak is found. c.  Close access doors (1). 4 Quarterly Engine, a.  Open access doors (1). Rocker Arm Cover b.  Inspect valve cover (9) for any Valve cover damage that visible damage or leaks. would interfere with rocker arm operation or class III leak is found. c.  Close access doors (1). 5 Quarterly Front, Service compressor by checking Compressor lubricating oil as follows: a.  Remove oil filler cap (10) and Lubricating oil is not check oil level in pipe.  Proper visible in elbow. quantity is indicated by lubricating oil level being visible in elbow (11). b.    Check condition of preformed Preformed packing packing (12). damaged. c.    Clean the adapter (13) with a wiping rag (item 2, section II, appendix E) and install oil filler cap (10). 4-13







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.