TM 9-4310-397-14 Table 4-1.  Preventive Maintenance checks and Services for 16MS125 - Continued Location Item No. Interval Procedure Not Fully Mission Capable If: Item to Check/Service 17- d.  Carefully remove clamp (84) and Cont fuel filter (85).  Discard fuel filter.  Contact your local environmental officer for guidance on how to dispose of oil filter in accordance with local regulations. e.  Install drain plug (83) and vent plug (82). f.  Clean any fuel spills with a wiping rag (item 2, section II, appendix E). g.  Install new fuel filter (85) (item 7, section IV, chapter 4) and clamp (84). h.  Close access doors (81). 18 1200 Engine, Service the valves by checking for Service Valves proper valve to rocker arm clearance Hours and adjusting if necessary. a.  Open access doors (86). b.  Carefully pull vent tube elbow (87) out of valve cover (88). 4-33