LO 5-4310-338-12
NOTES:
WARNING
1.
FOR OPERATION OF EQUIPMENT IN
Do not attempt to clean the element
or re-use the element because of its
PROTRACTED COLD TEMPERATURES BELOW -15F
clean appearance. Metal salts are
(-26C).
Remove lubricants prescribed in Key for
deposited on the element as the oil is
temperatures above -15F (-26C). Relubricate with
lubricants specified in Key for temperatures below -15 F
metal salts on the element will lower
(-26C).
If OEA lubricant is required to meet the
the flash point and can cause a fire in
temperature ranges prescribed in the Key, OEA lubricant
the separator. Destroy used element
is to be used in place of OE/HDO-10 lubricant for all
to prevent accidental re-use.
temperature ranges where OE/HDO-10 is specified in
8. WHEEL BEARINGS. Each 1000 hours, remove
wheels, clean and inspect all parts, replace worn or
2. OIL CAN POINTS. Each 50 hours, lubricate control
damaged parts, repack bearings, and assemble.
linkage, pins, springs, safety chains, doors and hinges,
latches, and all exposed adjusting threads with OE/HDO.
9. LUBRICANTS. The following is a list of lubricants
with military symbols and applicable specification
3. ENGINE OIL LEVEL HOT OR COLD CHECK. Oil
numbers.
level should be between high and low marks on dipstick
(allow to set 5 minutes before checking).
OE/HDO
MIL-L-2104
GAA
MIL-G-10924
4. ENGINE. Oil is to be changed each 100 hours.
OEA
MIL-L-46167
Drain when lubricant is warm.
(SD), Type II
P-D-680
5. ENGINE OIL FILTER. Each 100 hours, remove filter
Copy of this Lubrication Order will remain with the
element, clean housing and install new filter element.
equipment at all times, instructions contained herein are
After installing new filter element, fill crankcase, operate
mandatory.
engine for 5 minutes, check housing for leaks, check
crankcase oil level and bring between high and low
By order of the Secretary of the Army:
marks on dipstick.
JOHN A. WICKHAM, JR.
General, United States Army
remove filter element, clean housing and filter element.
Chief of Staff
Reassemble oil filter, operate compressor for 5 minutes,
check for leaks, check separator oil level and bring to
OFFICIAL:
"FULL" mark.
ROBERT M. JOYCE
Major General, United States Army
WARNING
The Adjutant General
Before servicing compressor oil
system, open service valve to
DISTRIBUTION:
atmosphere to relieve all pressure in
To be distributed in accordance with DA Form 12-25A
the system.
Operator
and
Organizational
maintenance
requirements for Rotary Air Compressors.
7. OIL SEPARATOR ELEMENT.
Each 4000 hours,
replace the oil separator element.
TA 220163
U.S. GOVERNMENT PRINTING OFFICE: 1984-420-903/274