TM 5-4220-227-14
5-8. Medical Lock (M/L) Inner Door Assembly.
This task covers:
a.
Replace
b.
Repair
INITIAL SETUP:
Tools
Materials/Parts (Cont.)
General Mechanics Tool Kit
Distilled Water (Item 9, Appendix E)
(NSN 5180-00-177-7033)
Teflon Tape (Item 21, Appendix E)
Cloth, Lint Free (Item 6, Appendix E)
Materials/Parts
Grease, Halocarbon (Item 13, Appendix E)
Medical Lock Inner Door Assembly
Equipment Condition
Valve Repair Kit
Preformed Packing Seal
Chamber shut down (para.
2-15).
Detergent, Nonionic (Item 8, Appendix E)
a. Replace. (figure 5-3)
(1) Loosen knob (1) and rotate swing bolt (2) away from inner lock door (3).
(2) Remove four nuts (4), two washers (5) and two allen head screws (6) and remove inner lock door (3).
(3) Install inner lock door (3) and install two allen head screws (6), two washers (5), and four nuts (4) but do not
tighten. Adjust nuts to allow doors to swivel on bolt hinge.
(4) Rotate swing bolt (2) to hook through door bracket (7) and tighten knob (1).
5-10