TM 5-4220-227-14
5-17. Portable Oxygen Analyzer Probe Assembly
This task covers:
a.
Replace
b.
Repair
INITIAL SETUP
Tools
Equipment Condition
General Mechanic's Tool Kit
Portable oxygen analyzer removed (para. 4-34).
(NSN 5180-00-177-7033)
Materials/Parts
Probe Assembly
a. Replace. (figure 5-14)
(1)
Remove two screws (1) and remove front cover (2) from housing (3).
(2)
Tag and disconnect electrical leads (4) and remove probe assembly (5) from housing (3).
(3)
Insert probe assembly electrical leads (4) through hole in back of housing (3).
(4)
Connect electrical leads (4) to analyzer.
(5)
Install front cover (2) on housing (3) and secure with two screws (1).
5-36