(5) Replace fuse block. (figure 6-28)
(a) Remove two screws (1) and pull cover (2) away from box (3).
(b) Tag and remove three fuses (11).
(c) Tag and disconnect leads from fuse block (12).
(d) Remove two nuts (13) and remove fuse block (12).
(e) Install new fuse block (12) and secure with two nuts (13).
(f) Connect and untag leads to fuse block (12).
(g) Install three fuses (11) as tagged.
(h) Install cover (2) on control box (3) and secure with two screws (1).
(6) Replace capacitor. (figure 6-28)
(a) Remove two screws (1) and pull cover (2) away from box (3).
(b) Tag and disconnect leads from capacitor (14).
(c) Remove screw (15) and strap (16) and remove capacitor (14).
(d) Install new capacitor (14) and secure with strap (16) and screw (15).
(e) Connect and untag leads to capacitor (14).
(f) Install cover (2) on control box (3) and secure with two screws (1).
FOLLOW-ON MAINTENANCE
Install low pressure control (para. 6-13).