TM 5-4220-233-14
2-2.
OPERATORS CONTROLS AND INDICATORS.
1
Cylinder Pressure Gauge (PI100 - PI107). 0 - 6,000 psi gauges used to determine pressure inside of
each storage cylinder.
2
1/4-Turn Ball Valves (MV108-115). 1/4 - turn ball valves used to isolate air from each storage cylinder to
the high pressure manifold.
3
Recharge Valve (MV116). Needle valve used to control flow of air from RECHARGE STATION to high
pressure manifold.
4
Manifold Valve (MV117). Needle valve used to control flow of air from the high pressure manifold to
HIGH - PRESSURE STATION or to pressure regulator (PR100).
5
High Pressure Valve (MV119). Needle valve used to control flow of air from high pressure manifold to
HIGH - PRESSURE port.
Figure 2-1. Servicing Unit Control and Indicators.