TM 5-4310-367-14
L05-2805-256-12
LUBRICATION ORDER
TO 38G2-102-2LC-1
27 JULY 1978
(Supersedes L05-2805-256-12,21 February 1977)
ENGINE, GASOLINE, 1-1/2 HP, MILITARY STANDARD MODELS
(MODEL 1A08-1) (MODEL 1A08-2) (MODEL 1A08-3)
Reference: TM 5-2806-256-14 and C9100-1 L
dry cleaning, or with OI L, fuel, diesel. Dry before lubri-
intervals and related task-hour times are based on normal
eating. Drain crankcase when HOT. Fill and check level.
you need to do all the services prescribed for a particular in-
The lowest level of maintenance authorized to lubricate a
terval. Change thE interval if your lubricants are contamin-
point is indicated by one of the following: (C) Operator/
ated or if you are operating the equipment under adverse
crew; or (0) Organizational Maintenance.
operating conditions, including longer-than-usual operating
hours. You may extend the interval during periods of low
You can help improve this publication. If you find any mis-
activity, but you must take adequate preservation precau-
take or if you know of a way to improve the procedures,
tions.
please let us know. Your letter or DA Form 2028 (Recom
mended Changes to Publications and Blank Forms) should
*The time specified is the time required to perform all ser-
be mailed directly to: Commander, U. S. Army Troop Sup-
vices at the particular interval.
port & Aviation Materiel Readiness Command, ATTN:
DRSTS-MTPS, 4300 Goodfellow Blvd. St. Louis, MO
Clean fittings before lubricating. Clean parts with SOLVENT
63120. A reply will be furnished to you
q TOTAL TASK-HR
q TOTAL TASK-HR
TASK-HR
INTERVAL
TASK-HR
INTERVAL
500
0.3
0.5
8
-- 1.5
50
--
INTERVAL q LUBRICANT
LUBRICANT q INTERVAL
500 OE/ Ignition Cam Wick
OE/
8
Crankcase Fill and
HDO (Sparingly) (0)
Level
HDO
(Check level) (see key)
CAUTION: When OES
oil is used the level
HDO (Drain and refill)
will be checked more
(0)
(C) often.
Model 1A08-3
CARD 1 OF 2
Figure 3-3. Lubrication order, engine (card 1 of 2)
Change 1