TM 5-4310-367-14
FUEL SYSTEM continued
REMARKS
ACTION
LOCATION/lTEM
4-15. CLEANING, INSPECTION AND REPAIR
Inspect for thread damage.
a.
Elbows ( 1 )
1.
b. Replace if damaged.
a.
Inspect for cuts or breaks.
2. Tubing (2)
b. Replace if cut or broken.
WARNING
When using compressed air
for blowing, air hose pressure
must not exceed 30 psig, and
individuals must wear eye
protective equipment.
If plugged, blow out with
c.
compressed air.
a. Clean off dirt with a rag.
3. Cap (3)
b. Inspect threads for dam-
age.
Replace if damaged.
c.
Inspect for cracks or
a.
4. Gasket (4)
crumbling.
b. Replace if damaged.
WARNING
Drycleaning solvent, P-D-680,
used to clean parts is poten-
tially dangerous to personnel
and property, Avoid repeated
and prolonged skin contact
by wearing rubber or solvent
impermeable gloves when
handling the solvent or ma-
terial wet with drycleaning
solvent. Wash hands imme-
diately after exposure with
soap and water and use a
lanolin based skin cream to
prevent skin drying. Do not
use near open flame or ex-
cessive heat. Flash point of
solvent is 100F (38C).
Ensure that ventilation ade-
quate to reduce solvent vapor
concentrations below accept-
able threshold limit values is
provided.
4-13