TM 5-4310-370-14
d. Reconnect the inflator gage hose by turning the bushing clockwise into the globe valve.
TM 5-4310-370-14/4-10
FIGURE 4-10. GLOBE VALVE REMOVAL AND REPLACEMENT
4-13. INFLATOR GAGE HOSE REPLACEMENT.
WARNING
Close globe valve tightly to avoid personal injury.
a. Disconnect inflator gage hose from globe valve by turning hose connection nut counter clockwise (figure 4-11).
b. Disconnect inflator gage hose from inflator gage by turning inflator gage counter clockwise until disconnected
c. Leave globe valve closed.
d. Replace inflator gage on to inflator gage hose by turning it clockwise until tight (figure 4-11).
e. Reconnect inflator gage hose to globe valve by turning hose connection nut clockwise until tight (figure 4-11).
f. Open globe valve and check connections for air leaks.
4-17