TM 5-4310-379-14
4-36.
Fixed 30 Gallon Air Receiver Fittings and Valves (Cont).
(9)
Drain valve and elbow. (figure 4-61)
(a)
Open valve (1) and release air pressure in receiver (2).
WARNING
Cleanliness is imperative in maintaining and handling diving air system components. All tools and parts
must be kept free of oil, grease, rust, or other contamination in accordance with accepted army diving
cleaning procedures. Foreign substances within an assembly could result in equipment failure and
possible injury or death to personnel.
Ensure that all air lines and components removed or openings into the air system that provides breathing
air are covered with a plastic bag and secured with a rubber band or taped shut. Small components
should be stored in a plastic bag and sealed. Failure to do so will cause air system to become
contaminated and could result in injury or death to the diver.
(b)
Loosen fitting nut (3) and remove drain hose (4).
(c)
Remove elbow (5)
(d)
Remove elbow (5) from hex nipple (6).
(e)
Remove hex nipple (6) from shutoff valve (7).
WARNING
Leave 1 1/2 threads exposed on fitting when applying teflon tape. This will ensure that no teflon tape will
hang down inside the air system. Teflon tape should be wrapped in such a manner that when the fitting is
tightened the tape will not loosen. Failure to wrap teflon tape correctly may result in contamination or
blockage of the air system and subsequent possible injury or death to the diver.
(f)
Apply teflon tape to all threads.
(g)
Install hex nipple (6) in shutoff valve (7).
(h)
Install elbow (5) on hex nipple (6).
(i)
Install drain hose (4) and tighten fitting nut (3).
(j)
Close valve (1).
4-142