TM 5-4310-379-144-42.Controls and Indicators (Cont).(2)Air temperature gage. (figure 4-69)(a)Open valve (1) and release air pressure in air receiver (2).WARNINGCleanliness is imperative in maintaining and handling diving air system components. All tools and partsmust be kept free of oil, grease, rust, or other contamination in accordance with accepted army divingcleaning procedures. Foreign substances within an assembly could result in equipment failure andpossible injury or death to personnel.Ensure that all air lines and components removed or openings into the air system that provides breathingair are covered with a plastic bag and secured with a rubber band or taped shut. Small componentsshould be stored in a plastic bag and sealed. Failure to do so will cause air system to becomecontaminated and could result in injury or death to the diver.(b)Loosen fitting nut (3) and remove air temperature sensor (4).(c)Remove two nuts (5), lockwashers (6), and brackets (7) and remove air temperature gage (8).(d)Install air temperature gage (8) and secure with two brackets (7), lockwashers (6), and nuts (5).(e)Install temperature sensor (4) and tighten fitting nut (3).4-162