3-20. Water Connections (Cont).
(2) Lower water connections. (figure 3-13)
(a) Open radiator cap (1) and pet cock (2) and drain coolant into suitable container.
(b) Loosen clamp (3) and clamp (4) and remove pipe (5).
(c) Loosen clamp (6) and remove adapter (7).
(d) Loosen clamp (8) and remove adapter (9).
(e) Install adapter (9) and tighten clamp (8).
(f) Install adapter (7) and tighten clamp (6).
(g) Install pipe (5) and tighten clamp (3) and clamp (4).
(h) Close pet cock (2).
(i) Fill radiator (10) with coolant and install radiator cap (1).