TM 5-4310-384-13
INSTALLATION.
CAUTION
The electrical components (motor, starter relay and heaters) are factory wired for 230 VAC power source.
The components may be rewired for 115 VAC power source. Be sure these components are wired
correctly to match available power source.
a.
Position electric motor (2) on tank saddle.
b.
Install, but do not tighten, mounting bolts, washers and nuts (1).
c.
Route conduit (8) and wires (9) into box (7) and secure with locknut.
d.
Connect motor leads (T1 and T2) in conduit box.
e.
Install cover plate (6) and screws (5) on conduit box (7).
f.
Install drive pulley and check alignment. Refer to paragraph 3-25.
g.
Install V-belts and adjust belt tension. Refer to paragraph 3-24.
h.
Tighten mounting hardware (1).
i.
Install the belt guard cover. Refer to paragraph 3-23.
j.
Reconnect main power.
3-48