TM 5-4310-386-14
5-10.
Lines and Fittings.
This task covers:
a.
Replace
INITIAL SETUP
Tools
Equipment Condition
General Mechanic's Tool Kit
Compressor unit shut down (para. 2-13).
(NSN 5180-00-177-7033)
Reference
Materials/Parts
Cleaning procedures, Chapter 4, Section VII
Tape (Item 25, Appendix E)
Bands, Rubber (Item 4, Appendix E)
Bags, Plastic (Item 3, Appendix E)
Replace.
(1)
Removal. (figure 5-9)
WARNING
Cleanliness is imperative in maintaining and handling diving system components. All tools and
parts must be kept free of oil, grease, rust, or other contamination in accordance with Chapter 4,
Section VII of this manual. Foreign substances within an assembly could result in equipment
failure and possible injury or death to personnel.
Ensure that all air lines and components removed or openings into the air system that provides
breathing air are covered with a plastic bag and secured with a rubber band or taped shut. Small
components should be stored in a plastic bag and sealed. Failure to do so will cause air system
to become contaminated and could result in injury or death to the diver.
(a)
Remove bolt (1) and loosen coupling nut (2) securing line (3) to filter block fitting (4) and remove line.
(b)
Remove filter block fitting (4) from filter block (5).
(c)
Loosen coupling nut (6) securing line (7) to elbow (8) on separator housing (9).
(d)
Loosen coupling nut (10) securing line (7) to fitting (11) and remove line.
(e)
Remove elbow (8) from fitting (12) and remove fitting (12) from separator housing (9).
(f)
Remove fitting (11) from fitting (13) and remove fitting (13) from elbow (14).
(g)
Remove elbow (14) from fitting (15) and remove fitting (15) from purification assembly (16).
5-30