TM 5-4310-386-14
5-50. Outer Frame (Cont).
b.
Repair. (figure 5-75)
WARNING
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive
heat. Flash point of solvent is 138oF (60oC).
(1)
Clean all items with dry cleaning solvent and dry thoroughly.
(2)
Inspect all threaded inserts (1) for stripped threads.
(3)
Inspect frame (2) for cracks, broken welds,or other damage.
(4)
Repair minor cracks and broken welds by welding.
(5)
Replace frame (2) if excessively damaged.
5-208