TM 5-4310-387-14
5-9.
Purifier Assembly (Cont).
c.
Repair. (figure 5-5)
WARNING
Cleanliness is imperative in maintaining and handling diving air system components. All tools
and parts must be kept free of oil, grease, rust, or other contamination in accordance with Chapter
4, Section VI of this manual. Foreign substances within an assembly could result in equipment
failure and possible injury or death to personnel.
Ensure that all air lines and components removed or openings into the air system that provides
breathing air are covered with a plastic bag and secured with a rubber band or taped shut. Small
components should be stored in a plastic bag and sealed. Failure to do so will cause air system to
become contaminated and could result in injury or death to the diver.
(1)
Remove purifier assembly (para. b.).
(2)
Unscrew cylinder (1) from base (2) and remove preformed packing (3), backup ring (4), and
purifier piston (5).
(3)
Remove cap (6) from cylinder (1).
(4)
Remove two bolts (7) and plate (8) from cap (6).
(5)
Inspect cylinder (1) and replace if cracked or threads are stripped.
(6)
Inspect base (2) and replace if threads are stripped.
(7)
Inspect cap (6) and replace if threads are stripped.
(8)
Inspect purifier piston (5) and replace if cracked, scored, worn, or otherwise damaged.
(9)
Discard preformed packings (3) and (10):
(10)
Inspect backup rings (4) and (9) and replace if bent or cracked.
(11)
Discard purifier cartridge (11).
(12)
Install plate (8) on cap (6) and secure with two bolts (7).
(13)
Apply halo carbon grease to new preformed packing (3).
(14)
Install backup ring (4), preformed packing (3), and base (2).
(15)
Install new purifier cartridge (11).
(16)
Install cap (6) on cylinder (1) and tighten.
(17)
Install purifier assembly (para. b.).
5-16