TM 5-4310-387-145-19.Lines and Fittings (Cont).f.ReplaceIntercoolertoSeparatorLine. (figure 5-22)WARNINGCleanliness is imperative in maintaining and handling diving air system components. All toolsand parts must be kept free of oil, grease, rust, or other contamination in accordance with Chapter4, Section VI of this manual. Foreign substances within an assembly could result in equipmentfailure and possible injury or death to personnel.Ensure that all air lines and components removed or openings into the air system that providesbreathing air are covered with a plastic bag and secured with a rubber band or taped shut. Smallcomponents should be stored in a plastic bag and sealed. Failure to do so will cause air system tobecome contaminated and could result in injury or death to the diver.(1)Loosen two connector nuts (1) and remove line (2).(2)Install line (2) and tighten two connector nuts (1).Figure 5-22. Intercooler to Separator Line, Replace.5-52