TM-5-4310-389-14
CAUTION
To avoid fatigue failure, the valves must be replaced every 2000 operating hours.
4. After completing all maintenance work on the valves, manually turn the compressor using the flywheel to
ensure components have been correctly installed.
5.
Check the valve space in the valve head for dirt; clean, if necessary.
6.
Discard old gaskets and 0-rings. Insert new gaskets and 0-rings on reassembly.
4-19