TM 5-4310-451-14
5-70. VARIABLE SPEED GOVERNOR HOUSING REPAIR.
This Task Covers:
a.
Disassembly
c.
Assembly
b.
Cleaning and Inspection
Initial Setup:
Equipment Conditions:
Materials/Parts:
ì Variable speed governor housing removed (see
ì Sealing compound (Item 14, Appendix E)
paragraph 5-69).
ì Grease (Item 22, Appendix E)
ì Lubricating oil (Item 28, Appendix E)
Tools/Test Equipment:
ì Dry cleaning solvent (Item 38, Appendix E)
ì General mechanics tool kit
ì One gasket
ì Field automotive shop set
ì One plug
ì Three lockwashers
General Safety Instructions:
ì Three retaining clips
ì Dry cleaning solvent Is flammable and must not be
used near open flame. Use only in a well-ventilated
area.
ì Compressed air used for cleaning purposes should
never exceed 30 psi (207 kPa).
a. DISASSEMBLY
1.
Place housing (1) in vise with soft jaws.
2.
Remove cap (5) and gasket (2) from housing (1).
Discard gasket.
3.
Bend tang of lockwasher (3) away from screw
(4).
4.
Remove screw (4) and lockwasher (3) from
housing (1). Discard lockwasher.
5.
Remove housing (1) from vise.
TA705129
5-260