TM 5-4310-451-14Table 4-2. Mechanical Troubleshooting (Con’t).MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONStep 4Check for plugged oil separator element.Replace oil separator element (see paragraph 4-90).15.IMPROPER UNLOADING CAUSING SAFETY RELIEF VALVE TO OPEN.Step 1Check pressure regulating valve adjustment.Adjust pressure regulating valve (see paragraph 2-11).Step 2Check for blocked pressure regulating valve Inlet.Remove and clean pressure regulating valve (see paragraph 4-87).Step 3Check for defective blowdown valve,Replace blowdown valve (see paragraph 4-88).Step 4Check for plugged element in oil separator.Replace oil separator element (see paragraph 4-90).Step 5Check for defective pressure regulating valve.Replace pressure regulating valve (see paragraph 4-87).Step 6Check for jammed governor and sullicon control linkage.Notify Direct Support Maintenance.Step 7Check for restrictions in sullicon control system lines.Clear restrictions or replace lines (see paragraph 4-40).16.START PRESSURE TOO HIGH.Step 1Check for blocked pressure regulating valve inlet.Remove and clean pressure regulating valve (see paragraph 4-87).Step 2Check for defective blowdown valve.Replace blowdown valve (see paragraph 4-88).17.EXCESSIVE VIBRATION.Step 1Check for loose fan hub.Tighten fan hub (see paragraph 4-48).Step 2Check for collapsed, torn, or loose engine motor mounts.Notify Direct Support Maintenance.4-12