TM 5-4310-452-14
2-2. CONTROLS AND INDICATORS (Con't).
Key
Component
Description
8
Service-air/Push After
This button controls the service air valve and allows the engine to warm up with a
Warm Up
minimum load. This button should be pressed only after the engine is warm. The
valve will reset automatically when the engine is turned off.
9
Pull To Stop
Stops the engine when pulled.
10
Ether Inject
Provides the engine with a burst of ether during cold weather start.
11
Start
Starts the engine.
12
Safety Circuit Bypass
Allows the safety circuit to be bypassed when starting the engine.
13
Light On/Off Switch
Controls the panel light above the indicator panel.
TA505396