TM9-4310-396-13Table 2-3 Operator/Crew Preventive Maintenance Checks and Services - continuedLocationItemItem toNot Fully MissionNo.IntervalCheck/ServiceProcedureCapable if:FUELTANK13BeforePrimary Fuel Tank Inspect primary fuel tank (1) andBroken nonmetallicnonmetallic tubing (2) are nottubing or leakingleaking fuel. Inspect for loose orfuel. Loose ormissing parts or damage.missing parts ordamage.14BeforeFuel TankInspect fuel tank assembly (3) andBroken nonmetallicAssemblynonmetallic tubing (4) are nottubing or leakingleaking fuel. Inspect for loosefuel. Loose oror missing parts or damage.missing parts ordamage.15BeforeNonmetallic Hose,Inspect nonmetallic hose (7), hoseLeaking fuel fromHose Adaptor, andadaptor (5), and hardware tononmetallic hose,Shutoff Screwinsure operable with no loose,hose adaptor, orCockleaking, or broken nonmetallichardware. Shutoffhose and hardware. Insurescrew cock isshutoff screw cock (6) is notleaking orleaking or damaged.damaged.WARNINGDo not smoke or use open flame when performing maintenancebecause fuel may ignite. Failure to observe this warning mayresult in severe personal injury or death.2-18