TM 9-4310-397-14Table 2-1. Preventive Maintenance Checks and Services for 16MS125 - ContinuedLocationItem No.IntervalProcedureNot Fully Mission Capable If:Item toCheck/ServiceEXTERIORWARNINGThe fuels in this compressor arehighly explosive. Do not makeor use open flame whenperforming maintenance.Flames and explosion couldresult in severe personal injuryor death.24DuringFuel TankService fuel tank (32) by checking fuel Fuel level is less than 1/4level. If less than 1/4 tank, shut down tank.engine. Top off with fuel (item 19,section II, appendix E) or (item 20,section II, appendix E) and re-startengine.25DuringAMMETERInspect AMMETER (33) indicatorIndicator reading outsidereading for normal operating range of 0normal operating range.to +15 amperes.2-18