TM 9-4310-397-14
Table 2-1. Preventive Maintenance Checks and Services for 16MS125 - Continued
Location
Item No.
Interval
Procedure
Not Fully Mission Capable If:
Item to
Check/Service
EXTERIOR
WARNING
The fuels in this compressor are
highly explosive. Do not make
or use open flame when
performing maintenance.
Flames and explosion could
result in severe personal injury
or death.
24
During
Fuel Tank
Service fuel tank (32) by checking fuel Fuel level is less than 1/4
level. If less than 1/4 tank, shut down tank.
engine. Top off with fuel (item 19,
section II, appendix E) or (item 20,
section II, appendix E) and re-start
engine.
25
During
AMMETER
Inspect AMMETER (33) indicator
Indicator reading outside
reading for normal operating range of 0
normal operating range.
to +15 amperes.
2-18