TM 5-4220-227-14 Table 4-2.  Unit Troubleshooting Procedures (Cont). MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 8. HEATER/CHILLER OR SCRUBBER FAIL TO OPERATE. Step 1.  Check fuse on panel. Replace blown fuse. Step 2.  Place scrubber switch on panel to ON.  Scrubber fan should rotate.  Place heater/chiller switch on panel to ON.  Heater/chiller fan should rotate. If either scrubber or heater/chiller fails to operate, notify Direct Support Maintenance. Step 3.  Both scrubber and heater/chiller fail to operate. DC power is faulty.  Notify Direct Support Maintenance. 9. HEATER/CHILLER FAILS TO OPERATE. Step 1.  Inspect fluid output, check valve.  It may be stuck in the closed position causing low output pressure. Refer to General Support Maintenance. NOTE For additional information, see figure 6-16 Heater/Chiller Module Flow Diagram. Step 2.  Inspect valves at the chamber penetrator.  They may be closed or partly closed causing low output pressure Open valves. Step 3.  Inspect fluid level in reservoir.  It may be low and causing low output pressure. Add fluid. Step 4.  Inspect pump fuse.  It may be blown, interrupting electrical power to the pump. Replace fuse. 4-19