OIL FILLER CAP, BREATHER CAP, PLUG, AND SIGHT GAGE.
Figure 3-22. Oil Filler Cap, Breather Cap, Plug, and Sight Gage, Installation.

TM-5-4310-380-13 Compressor Unit Reciprocating 15 CFM 175 PSI Electric Motor Driven Model:10HT8G Manual
Page Navigation
  54    55    56    57    58  59  60    61    62    63    64  
TM 5-4310-380-13
3-18. OIL FILLER CAP, BREATHER CAP, PLUG, AND SIGHT GAGE - Continued.
a. Removal. (Refer to Figure 3-21).
Figure 3-21. Oil Filler Cap, Breather Cap, Plug, and Sight Gage, Removal.
(1) Remove oil filler cap (1) and gasket (2).
(2) Remove oil plug (3), elbow (4), and nipple (5).
(3) Remove breather cap (6), ball (7), body (8), and gasket (9).
(4) Remove four screws (10), cover (11), seal (12), and oil gage (13) from the crankcase (14). Discard seal
(12).
b. Cleaning.
(1) Remove all buildup of dirt, grease, etc. by wiping with a soft cloth (Appendix E, item 3).
WARNING
Cleaning Solvent, Federal Specification P-D-680, is toxic and flammable. Use solvent only in a
well-ventilated area. Avoid prolonged breathing of fumes. Keep solvent away  from flames.
Do not use in excessive amounts. Avoid skin contact.
(2) Clean using a clean, soft cloth (Appendix E, item 3) or a medium bristle brush (Appendix E, item 4) and
cleaning solvent (Appendix E, item 2).
(3) Allow to dry.
GO TO NEXT PAGE