  202    203    204    205    206  207  208    209    210    211    212  
TM 5-4310-386-14 Table 5-1.  Direct Support Troubleshooting Procedures (Cont). MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 5.  SIGHT GLASS EXHIBITS AIR BUBBLES. Step 1.  Check oil pressure regulator. Clean and adjust regulator (para.  5-12). Step 2.  Check oil pump final pressure. Clean or replace (para.  5-11). Step 3.  Check 4th stage valve head assembly. Replace or repair 4th stage valve head assembly (para.  5-23). 6.  COMPRESSOR DOES NOT AT-AIN FINAL PRESSURE. Step 1.  Check fourth stage safety valve. Replace a defective fourth stage safety valve (para.  5-24). Step 2.  Check interfilter drain valves. Clean, repair, or replace (para.  5-17). Step 3.  Check interfilter safety valves. Replace any safety valve that is defective (para.  5-16). 7.  EXCESSIVE VIBRATION OF UNIT. Step 1.  Fuel injection pump timing off. Check, adjust if necessary (para.  5-30). Step 2.  Frame cracked. Weld, replace as necessary (para.  5-49). 5-4