4-60.  SLAVE RECEPTACLE REPLACEMENT.
b. INSTALLATION - TM-5-4310-452-14_177

TM-5-4310-452-14 Compressor Air: Rotary Screw 750 CFM 100 PSI Wheel-Mounted DED SULLIAR Model 750 DP Manual
Page Navigation
  163    164    165    166    167  168  169    170    171    172    173  
TM 5-4310-452-14 4-61.  MAGNETIC STARTER SWITCH REPLACEMENT. This Task Covers: a.  Removal b.  Installation Initial Setup: Equipment Conditions: Materials/Parts: • Four lockwashers •  Engine off. •  Right door assembly open. Tools/Test Equipment: •  Battery cables disconnected (see paragraph 4-57). •  General mechanic's tool kit a. REMOVAL 1. Remove 2 screws (5) from bracket (6). 2. Remove   2   nuts   (10),   lockwashers   (9),   and   3   electrical   leads   (8)   from   magnetic   starter   switch   (4).      Discard lockwashers. 3. Remove 2 nuts (1), lockwashers (2), and electrical leads (11) from magnetic starter switch (4).  Discard lockwashers. 4. Remove 2 screws (3), nuts (7), and magnetic starter switch (4) from bracket (6). 4-114