  165    166    167    168    169  170  171    172    173    174    175  
TM 5-4310-452-14 4-62.  SHUTDOWN RELAY REPLACEMENT. This Task Covers: a.  Removal b.  Installation Initial Setup: Equipment Conditions: Materials/Parts: •  Two self -locking nuts •  Engine off. •  Two self-locking nuts •  Left door assembly open. •  Battery cables disconnected (see paragraph Tools/Test Equipment: 4-57). •  General mechanic's tool kit a. REMOVAL 1. Disconnect   5   electrical   leads   (5)   from   shutdown relay (1). 2. Remove   2   self-locking   screws   (3),   nuts   (2),   and shutdown  relay  (1)  from  control  panel  (4).    Discard self-locking screws and nuts. b. INSTALLATION 1. Position shutdown relay (1) in place on control panel (4) and install 2 new self-locking screws (3) and nuts (2). 2. Connect 5 electrical leads (5) to shutdown relay (1). FOLLOW-ON TASKS: •   Connect battery cables (see paragraph 4-57). •   Close left door assembly. TA505498 4-116