TM-5-4310-452-14 Compressor Air: Rotary Screw 750 CFM 100 PSI Wheel-Mounted DED SULLIAR Model 750 DP Manual
Page Navigation
  28    29    30    31    32  33  34    35    36    37    38  
TM 5-4310-452-14 Table 2-1.  Operator Preventive Maintenance Checks and Services (PMCS) (Con't). B-Before D-During A-After W-Weekly Interval ITEM TO BE INSPECTED Equipment is Item PROCEDURE: Check for and have repaired Not Ready No. B D A W filled or adjusted as needed Available If: 1 UNLOADER VALVE ASSEMBLY WARNING Unloader valve assembly may be under pres- sure. Protect eyes and skin from unloader draincock opening during draining proce- dure. During compressor warm-up and before service air button is pushed to build air pressure, open draincock (10) and drain moisture from unloader valve assembly (9). 17 STORAGE BATTERY WARNING • Storage battery acid (electrolyte) Is extreme- ly dangerous. Always wear goggles and rub- ber gloves when performing battery checks or Inspections. Serious Injury to personnel will result If battery acid contacts skin or eyes. •  DO NOT perform storage battery checks or inspections while smoking or near fire, flames, or sparks. Storage batteries may ex- plode, causing serious Injury or death to per- sonnel. NOTE If compressor unit has a maintenance-free storage battery, perform only step b. a.    Check electrolyte level in storage batteries. If electrolyte level is below top of plates, notify your supervisor. b.    Check storage battery and storage battery box Storage battery is missing or for corrosion and obvious damage. If corrosion engine will not crank. or damage is found, notify your supervisor. TAS06402 2-14







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.