TM 5-4220-233-14Table 2-1. Operator Preventive Maintenance Checks and Services (PCMS) ContinuedItemItemNot MissionNo.Intervalto Check/ServiceProcedureCapable if:11BeforeControla. Check the gauges for obvious damage.Broken gauges.PanelDuringAssemblyb. Check the movement and operation of the gaugesGauges not operatingduring filling, recharge, or depressurization.properlyAfterc. Cover all fill station recharge andHIGH PRESSURE ports with dust caps.d. Ensure all control panel valves are closed and theregulator is adjusted out.12AfterDoora. Ensure that front doors are closed and secured.Assembly13BeforeCylindera. Fully close all cylinder valves (MV100-MV107)Assemblyb. Check to ensure the eight stored cylinders are Missing or loosetight against the control compartment bulkhead.clamps.c. Check for sixteen cylinder clamps and Missing or loosesecurely tighten.clamps.d. Ensure the three quick-release pins are fullyengaged onthe two cylinder holddown Quick release pinsbrackets and the adjustable stopsmissing.are tight against the bottom of each cylinder.2-13