TM 5-4310-275-14
(4) Reduce the intervals between condensate
2-10. Operation Under Rainy or
Humid Con-
blow downs as necessary to assure the delivery of
ditions
dry, pure air.
2-11. Operation in
Salt Water Areas
operated outdoors, erect a suitable shelter or
cover the unit with the canvas cover when not in
a. General, Salt water causes corrosive action
use. During dry periods, remove the canvas cover
on metal. Wash the unit frequently with fresh,
to allow the unit to dry out.
clean water.
b. Lubrication.
b. Lubrication.
(1) Refer to LO 5-2805-257-14 for engine
(1) Steam clean the entire unit, if such
equipment is available, before lubricating.
accordance with Lubrication Chart (fig. 3-1 ).
(2) Clean and dry all fittings before
(2) Keep rain from entering the system when
lubricating.
lubricating the unit.
(3) Refer to LO 5-2805-257-14 for engine
(3) Keep the crankcase oil fill, breather cap,
and the level gage tight at all times.
c. Fuel System.
c. Fuel Systems.
(1) Keep the fuel tank full at all times to
(1) Keep the fuel tank cap tight at all times.
(2) Service the fuel filter daily.
(2) Keep the fuel tank cap tight at all times.
(3) Store the fuel in clean, dry containers.
(3) Service the fuel filter daily.
d. Electrical System.
d. Electrical Systems.
(1) Clean and dry all electrical connections
(1) Keep electrical leads, spark plugs, and
and check for corrosion.
magneto wiped dry.
(2) Check all gages for loose or broken lenses
(2) Check electrical leads for cracked or
which might permit entry of moisture. Repair or
frayed insulation.
tape the lenses to prevent entry of moisture.
(3) Check all gages for loose or broken lenses
which might permit entry of moisture. Repair or
tape the lenses to prevent entry of moisture.