TM 5-4310-343-35
Trouble
Probable cause
Remedy
Eccentric or high mica on
Grind and true commutator.
Under-
commutator.
Weak or broken brush springs.
Check brush springs and verify
Brushes too short.
Brush chatter or hissing noise.
Loose brushes, insufficient brush
Check for worn brushes and
spring tension
High mica.
Poor brush fit on commutator
Brushes binding in the brush
Remove and lea brush holders.
holders.
Remove my irregularities on inside
surface of brush holder or brush.
Brushes wear rapidly.
Rough commutator.
Resurface commutator and
undercut mica (para 6-4).
Armature overheats.
Defective armature winding.
Check commutator for internal
shorts. Remove any metallic
particles (para 6-4).
Excessive vibration.
Check bearing for defects
Replace defective
bearing
4-8A