Low interstage pressure
Excessive blow-by.
TM-5-4310-343-35 Compressor Air Reciprocating Base Mounted 4 CFM 3000 PSI Electric Motor Drive (Walter Kidde MDL 895026) (Bogue Electric MDL 6703) Manual
Page Navigation
5
6
7
8
9
10
11
12
13
14
15
TM
5-4310-343-35
Trouble
Probable
Cause
Remedy
High
interstage
pres-
Heads
improperly
posi-
Position
head
in
proper
sure.
tioned.
position.
Refer
to
"in"
and
"out"
markings
on
head.
Clogged
intercoolers.
Clean
or
replace
faulty
component.
Sticking
intake
or
Clean
and
if
necessary,
discharge
valve.
For-
re-lap
valve
and
seating
eign
matter
between
in-
surface.
take
valve
and
seating
surface.
Intake
or
discharge
valves
im-
properly
lapped.
Incorrect
heed
clearance
Check
and
adjust
head
or
valve
travel.
clearances
and
valve
travel.
Excessive
blow-by.
Rings,
cylinders,
Measure
blow-by
at
the
plungers,
or
pistons
port
(138,
Fig.
6-1)
worn
or
scored
or
in-
located
at
the
bottom
correctly
assembled,
or
of
the
drive
mounting
poor
fit
of
parts.
flange
of
the
crankcase
.
4-5