5-7.
INSTALLATION INSTRUCTIONS
Bolt the compressor unit securely and evenly to a level barn. Where the base isn't completely level use shims under the
feet. Do not eliminate space between the base and a foot by drawing the foot down. This would put strain on the unit.
Secure mounting of the base is necessary to minimize vibration.
Leave sufficient space around the compressor so that it is accessible from all sides for maintenance.
Mount the
compressor with the pulley side toward the wall and at least 6 inches (18 cm) away from it.
Connect the motor starter to a 120 VAC single phase power source. The source must have a separate on off switch for
the compressor.
Section III. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
5-8.
INTRODUCTION
The preventive maintenance checks and services listed in the PMCS table cover procedures to be performed by
organizational maintenance personnel.
5-9.
PMCS TABLE
Explanation of the columns
Item Number. Checks and services are numbered in sequence. This column shall be used as source of item
numbers for the TM Number Column on DA Form 2404, Equipment Inspection and Maintenance Worksheet, in
recording results of PMCS.
Item To Be Inspected. This column gives the name of the item to be inspected or serviced.
Procedures. This column lists inspection procedures.
Equipment Will Be Reported Not Ready/Available If: This column contains the criteria which will cause the
equipment to be classified as not ready or not available because of inability to perform its primary mission.
5-3