TM 5-4310-367-14
CYLINDER HEAD, CYLINDER AND VALVE continued
ACTION
REMARKS
LOCATION/lTEM
4-24. CLEANING, INSPECTION AND REPAIR.
1.
Wash with detergent solution.
Air filter
WARNING
Drycleaning so Ivent, P-D-680,
used to clean parts is poten-
tially dangerous to personnel
and property. Avoid repeated
and prolonged skin contact
by wearing rubber or solvent
impermeable gloves when
handling the solvent or ma-
terial wet with drycleaning
solvent. Wash hands immedi-
ately after exposure with
soap and water and use a
lanolin based skin cream to
prevent skin drying. Do not
use near open flame or ex-
cessive heat, Flash point of
solvent is 100F (38C).
Ensure that ventilation ade-
quate to reduce so Ivent vapor
concentrations below accept-
able threshold limit values is
provided.
Do not use solvent on air filters.
Clean with drycleaning sol-
2. All parts
vent P-D-680.
a. Inspect for flatness and
3. Low pressure reed
absence of nicks.
valve
b. If bent or nicked, replace.
4-26