TM 5-4310-367-14
GENERAL continued
REMARKS
ACTION
LOCATION/lTEM
I
I
5-7. CLEANING, INSPECTION AND REPAIR.
WARNING
Drycleaning soIvent P-D-680,
used to clean parts is poten-
tially dangerous to personnel
and property. Avoid repeated
and prolonged skin contact
by wearing rubber or solvent
impermeable gloves when
handling the solvent or ma-
terial wet with drycleaning
solvent. Wash hands immedi-
ately after exposure with soap
and water and use a lanolin
based skin cream to prevent
skin drying. Do not use near
open flame or excessive heat.
Flash point of solvent is
100 F (38C). Ensure that
ventilation adequate to re-
duce solvent vapor concen-
trations below acceptabIe
threshold limit values is
provided.
Clean with drycleaning sol-
1. All parts
vent P-D-680.
a. Inspect for pitting, galling
2. Crankshaft bearings
or signs of wear.
are bad.
Inspect for cracks, scoring
a.
3. Crankshaft
and excessive wear.
b. Replace if cracked,
scored, or excessively
worn.
c. Check crankshaft journals
for out-of-round.
d. If journals measure more
than 0.0004 in. out-of-
round, replace crankshaft.
5-6