TM 5-4310-370-14
c. Disconnect motor cable from junction box by removing cable connection nut as shown in figure 4-3.
d. Reconnect motor cable to junction box and replace cable connection nut.
e. Reconnect starter switch and motor leads by twisting leads togethe r and replacing wire nuts.
f. Replace junction box gasket, junction box cover, and replace junction box screws by turning them clockwise.
TM 5-4310-370-14/4-3
FIGURE 4-3. STARTER SWITCH-MOTOR DISCONNECT
4-7. MOTOR REPLACEMENT.
WARNING
Disconnect compressor unit from main power supply before servicing, replacing
or repairing parts of equipment, to avoid personal injury.
4-9