TM 5-4310-373-14
REMARKS
ACTION
LOCATION/lTEM
5-7. COMPRESSOR ASSEMBLY/INSPECTION/CLEANING - continued
WARNING
Drycleaning solvent, P-D-680,
used to clean parts is poten-
tially dangerous to personnel
and property. Avoid repeated
and prolonged skin contact
by wearing rubber or non-
porous gloves when handling
the solvent or material wet
with drycleaning solvent.
Wash hands immediately
after exposure with soap and
water and use a lanolin based
skin cream to prevent skin
drying. Do not use near open
flame or excessive heat. Flash
point of solvent is 100F
(38C). Do not work with
solvent in a closed room. Be
sure there is good ventilation
or the solvent vapors will
build up in the air and be-
come a poisonous mixture
which can cause physical
injury or even death.
WARNING
Clean with compressed air no
greater than 30 psi.
WARNING
Protective eyeware must be
worn when using compressed
air.
a. Clean with solvent
assembly
b. Blow out with compressed
air.
c. Dry with clean rag.
5-18