TM 5-4310-377-13
3-24. CHECK VALVE - Continued.
Figure 3-35. Check Valve, Removal.
(2) Disconnect pressure switch unloader tube (2).
(3) Remove check valve (3).
(4) Remove elbow (4).
b. Cleaning.
(1) Remove all buildup of dirt, grease, etc. by wiping with a soft cloth (Appendix E, item 3).
WARNING
Cleaning Solvent, Federal Specification P-D-680, is toxic and flammable. Use
solvent only in a well-ventilated area. Avoid prolonged breathing of fumes. Keep
solvent away from flames. Do not use in excessive amounts. Avoid skin contact.
(3) Allow to dry.
GO TO NEXT PAGE
3-66