TM 5-4310-379-14
3-28. Air Cleaner Assembly (Cont).
c.
Repair. (figure 3-33)
(1)
Remove wingnut screw (1), seal (2) and retainer (3) and remove air cleaner cover (4), body (5) and gasket
(6).
(2)
Pour excess oil from body (5) into suitable container.
(3)
Remove element (7).
WARNING
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive
heat. Flash point solvent is 100-138°0F (38-60°C).
(4)
Clean all items, except seal, with dry cleaning solvent and dry thoroughly.
(5)
Inspect wing nut screw (1), and replace if threads are stripped or otherwise damaged.
(6)
Inspect cover (4) and gasket (8) and replace a cover that is dented or cracked, or a gasket (8) that is
cracked or otherwise damaged.
(7)
Inspect element (7) and gasket (9). Replace element (7) that is unserviceable or a gasket (9) that is
cracked or otherwise damaged.
(8)
Inspect body (5) and gasket (6). Replace a body (5) that is dented or cracked, or a gasket (6) that is
cracked or otherwise damaged.
(9)
Inspect seal (2) and replace if ripped or otherwise damaged.
(10)
Inspect retainer (3) and replace if bent or otherwise damaged.
(11)
Fill body (5) with engine oil to LEVEL line.
(12)
Install element (7).
(13)
Install gasket (6), body (5), cover (4) and secure with wing nut screw (1), retainer (3) and seal (2).
3-86