TM 5-4310-379-14
4-40. Portable 60 Gallon Air Receiver Gages.
This task covers:
Replace
INITIAL SETUP
Tools
Materials/Parts (Cont)
General Mechanic's Tool Kit
(NSN
5180-00-177-7033)
Tape (Item 24, Appendix D)
Bands, Rubber (Item 5, Appendix D)
Materials/Parts
Bags, Plastic (Item 4, Appendix D)
Tape, Teflon (Item 25, Appendix D)
Gage, Pressure
Pneumofathometer
Replace. (figure 4-66)
WARNING
Cleanliness is imperative in maintaining and handling diving air system components. All tools and parts
must be kept free of oil, grease, rust, or other contamination in accordance with accepted army diving
cleaning procedures. Foreign substances within an assembly could result in equipment failure and
possible injury or death to personnel.
Ensure that all air lines and components removed or openings into the air system that provides breathing
air are covered with a plastic bag and secured with a rubber band or taped shut. Small components
should be stored in a plastic bag and sealed. Failure to do so will cause air system to become
contaminated and could result in injury or death to the diver.
NOTE
There is one pressure gage and three depth gages. Replacement of each depth gage is the same.
(1)
Remove depth gage (1) from tee (2).
(2)
Remove pressure gage (3) from reducer (4) on union elbow (5).
WARNING
Leave 11/2 threads exposed on fitting when applying teflon tape. This will ensure that no teflon tape will
hang down inside the air system. Teflon tape should be wrapped in such a manner that when the fitting is
tightened the tape will not loosen. Failure to wrap teflon tape correctly may result in contamination or
blockage of the air system and subsequent possible injury or death to the diver.
4-156