TM 5-4310-379-14
Parts Needed: Terminal lug (PN MS35425-40) (96906) 2 ea, Wire (PN M13486/1-2) (96906) 24.50 in. (62.23 cm),
Tubing, heat shrink 2 pieces 1 in. (2.54 cm) long.
Figure F-3. Positive Battery Cable.
NOTES
1.
All dimensions in inches.
2.
Cut wire to length.
3.
Strip off insulation.
4.
Install terminal lugs and crimp.
5.
Install heat shrink tubing on terminals to cover gap
between terminals and insulation.
F-4