Parts Needed: Connector (PN NPN-24) (19099) Connector (PN NPN-25) (19099), Wire (PN M5086/1-14-9) (96906) 8 in.
(20.32 cm), Wire (PN M5086-1-14-2) (96906) 5 in. (12.70 cm), Terminal Lug (PN MS25036-156) (96906)
4951-236
Figure F-8. Alternator Wiring.
NOTES
1.
All dimensions in inches.
2.
Cut all wires to length.
3.
Strip off insulation.
4.
Install terminal lug and crimp.
5.
Install connectors and secure wires to connectors.