TM 5-4310-382-13
2-14. OPERATION IN SALT AIR, SEA SPRAY, OR HIGH HUMIDITY. Shelter unit from sea spray as much as possible
while still maintaining a well-ventilated operating area and perform the following procedures:
a. Frequently wipe all components of
the air compressor unit to
dry excessive moisture on
unit.
b. Open the drain cock more often to drain all moisture from air tank.
c. Cover unit completely when not in use.
2-15. OPERATION IN DUSTY OR SANDY AREAS. Shelter the unit from sand and dust as much as possible and
perform the following procedures:
a. Inspect the air filters for both the engine and the air compressor frequently.
b. Keep engine and air compressor cooling fins clean.
c. Cover unit completely when not in use.
2-18