TM 5-4310-384-13
Class III
Leakage of fluid great enough to form drops that fall from the item being checked/inspected.
CAUTION
Equipment operation is allowable with minor leakages (Class I or II). Consider the fluid capacity in the item/system being
checked/inspected. When in doubt, notify your supervisor.
When operating with Class I or Class II leaks, continue to check fluid levels as required by PMCS table.
Class III leaks should be reported to your supervisor.
Table 2-1. Operator's Preventive Maintenance Checks and Services
B
-
Before Operation
D
-
During Operation
A
-
After Operation
W
-
Weekly
1
COMPRESSOR DRIVE SYSTEM
a.
Inspect belt guard mounting screws (1).
Belt guard is damaged
or loose enough to
obstruct motion of
b.
Inspect belt guard mounting bolts (2) to tank.
pulley, flywheel or belts.
c.
Inspect belt guard (3) for damage.
ITEM
NO.
INTERVAL
ITEM TO BE INSPECTED. PROCEDURE:
EQUIPMENT NOT
READY/AVAILABLE IF:
B D A W
2-3