TM 5-4310-384-13
REMOVAL.
WARNING
Disconnect and tag main power source and turn compressor unit OFF before performing maintenance
procedures. Voltages present in this equipment can cause injury or death.
a.
Turn key (1) to open cover (2) on enclosure (3).
b.
Disconnect and tag all wires (4 and 5) from starter assembly (6) and toggle switch (7).
c.
Remove conduit locknuts (8) and pull conduits from enclosure (3).
d.
Remove thermostat (9). See paragraph 3-20.
e.
Remove bolts, nuts, and washers (10) and enclosure from saddle frame (11).
f.
Remove two screws (12) and starter assembly (6).
g.
Remove nut (13), ON/OFF plate (14) and toggle switch (7) from enclosure.
INSTALLATION.
a.
Position toggle switch (7) and ON/OFF plate (14) on enclosure and secure with nut (13).
b.
Install screws (12) and starter assembly (6).
c.
Push conduit and wires through holes in enclosure and secure with locknuts (8).
d.
Install thermostat (9). See paragraph 3-20.
e.
Install bolts, nuts, and washers (10) and enclosure (3) to frame (11).
f.
Connect all wires (4 and 5) to starter assembly (6) and toggle switch (7).
CAUTION
Recheck all wiring connections before turning main power on. If not sure, refer to wiring diagram.
g.
Close enclosure cover (2).
h.
Reconnect main power.
3-17